Therapy Longevity

With Axonics® SNM, the choice between a rechargeable and recharge-free neurostimulator comes without compromising therapy longevity.

Recharge-Free SNM System

Longest-Lived. Truly Recharge-Free.

  • 17.6 year battery life at 1mA and over 20 years at lower energy settings1*
  • Patients do not recharge any system components

Rechargeable SNM System

Long-Lasting Therapy with Minimal Recharging

  • Open-ended battery life, designed to last 20+ years
  • 6 to 10 month recharge interval**

Smart Programming

Advanced Programming Capabilities Ensure a Fuss-Free Patient Experience

Designed to optimize programming to get it right the first time, our proprietary Smart Programming algorithm:

  • Determines program recommendations based on lead placement and intraoperative responses
  • Predicts effective programming at implant, resulting in minimal need for reprogramming3
  • Minimizes the need for patients to adjust their program3
  • Maintains optimal stimulation level with constant current stimulation

of patients were on one of their top two recommended programs after 1 year3

Remote Control

Easy to Use Design:

  • Conveniently pocket-sized and recharge-free
  • Does not require external antennas or communicators
  • Enables patient to easily adjust therapy amplitude and change between 2 personalized programs
  • Allows MR technician to check system readiness before fully-body MRI

Patients Prefer the Axonics Patient Remote Control

In a survey of 148 patients that used both the InterStim® Samsung Programmer and the Axonics Patient Remote Control, results showed:

of the patients prefer the Axonics Remote Control4

of the patients said the Axonics Remote Control is easier to use4

Tined Lead

Durable Tined Lead for Reliable Therapy

Axonics tined leads are thoughtfully designed to be robust and to provide long-term symptom relief.

  • Interchangeable tined lead, compatible with both R20 rechargeable and F15 recharge-free SNM systems
  • Patented helical-tined design to mitigate lead migration
  • Visible and radiopaque markers for lead implantation

Click here to uncover why tined lead performance matters

References:

* Default stimulation settings for both Axonics and Medtronic are shown at Frequency 14 Hz, Pulse Width 210 μs.

** Depending on therapy settings

  1. Company data on file. 110-0022-002rA
  2. Battery life from InterStim X® System specifications Manual M988757A016 Rev B
  3. ARTISTRY Registry data on file. October 2023
  4. Company data on file 105-0124-001

InterStim and InterStim X are registered trademarks of Medtronic, Inc.